GARTECHBlinds — Service and Installation Request a consultation
Metering daylight

Venetian blinds

The slat is the only part of a house that does not merely pass or block light but steers it. One degree of tilt decides whether the sun lands on your screen or on the ceiling.

No visible tapes

All-metal blind GM 200

The mechanism sits in the side guides, not in the curtain. So not one cord crosses the slats — the surface stays calm, the slats close tight, and nothing is in the way when you clean them.

What it is built for

Where the façade is part of the design and a taped blind would spoil it. The built-in anti-lift device also makes it a deterrent on the ground floor.

What that means day to day

Maximum blackout, because the slats close without tape holes. Very wind-stable. And robust enough that you simply use it for twenty years.

Clear height (hl)
min. 560 mm – max. 4,000 mm
Width (bk)
min. 600 mm – max. 3,000 mm
Lintel depth (tn)
120 mm
Maximum area, single
8 m²
Maximum area coupled, manual drive
8 m²
Maximum area coupled, motor
20 m²
Retract at wind speed
92 km/h (wind resistance class 6)
Source and conditions

Source: Technical Specifications Brochure — Slat blinds, Fabric blinds, Roller shutters, Shutter, edition 03/2026, page 4.

  • For designs with a protective roof, add 5 mm to the lintel height.
  • Smaller limits apply to extruded and angular slats.

Technical drawings

Section through the lintel with the box dimensions
Section through the lintel with the box dimensions
Installation and mounting dimensions
Installation and mounting dimensions

Technical drawings from the Schenker Storen technical brochure, edition 03/2026.

An all-metal blind on a concrete façade in afternoon light
Ganzmetallstoren GM 200 über die volle Länge eines Laubengangs, Lamellen halb geöffnet

Detail photographs Schenker Storen

Locked at every position

Metal composite blind MV 90

Instead of lift tapes, a toothed belt runs inside the side guide. That removes the part that ages fastest on a blind — and the blind is locked at every intermediate position, not only at the bottom.

What it is built for

Ground floors and anywhere security matters. The anti-lift and run-up devices are part of the construction, not accessories.

What that means day to day

A deeply overlapping slat profile that closes precisely and stays quiet. The tapered bottom rail sits flush on the sill.

What sets it apart

Z-shaped slat profile. No lift tapes — the quiet toothed belt runs unseen inside the guide rail. That allows optimal blackout and thermal insulation. The anti-lift lock is built in, not bolted on. Minergie certified. Mounted in the lintel or as a front installation. Hand-operated or controlled by remote, wall switch or smart-home system. Optionally with soft-closing for a quieter close and a steadier slat movement.

Clear height (hl)
min. 600 mm – max. 4,000 mm
Width (bk)
min. 508 mm (manual) / 550 mm (motor) – max. 3,800 mm The minimum width depends on the drive.
Lintel depth (tn)
130 mm
Maximum area, single
8 m²
Maximum area coupled, manual drive
8 m²
Maximum area coupled, motor
12 m²
Retract at wind speed
92 km/h (wind resistance class 6)
Source and conditions

Source: Technical Specifications Brochure — Slat blinds, Fabric blinds, Roller shutters, Shutter, edition 03/2026, page 5.

  • The sales sheet gives 510 mm as the minimum width, rounded. The technical brochure gives 508 mm for manual drive.
  • For designs with a protective roof, add 5 mm to the lintel height.

Technical drawings

Section through the lintel with the box dimensions
Section through the lintel with the box dimensions
Installation and mounting dimensions
Installation and mounting dimensions

Technical drawings from the Schenker Storen technical brochure, edition 03/2026.

MV metal composite slat blinds on a timber-and-concrete building, half closed
Geschlossener MV-Behang über die volle Fensterhöhe Z-förmige Lamellen der MV aus nächster Nähe, leicht geöffnet Looking up at a run of opened slats

Manufacturer photograph Schenker Storen

The all-rounder

Composite blind VR 70 / VR 90

The blind that suits most houses — and the one we fit most often. Two slat widths, several guide systems, and it retrofits to many existing façades.

The difference between 70 and 90

VR 90 has 90 mm slats, VR 70 has 70. Wider means fewer slats across the opening and a calmer façade; narrower means less room needed in the lintel and finer control.

Guides

Profile or cable guides, or both together where it is windy. Mounted in the lintel, behind a fascia or hung in front — the building decides that, not the catalogue.

What can be added

Wind-stable version up to 92 km/h. Integrated insect screen — available only with the 70 mm slat, which can be a reason against the wider one. Acoustic brackets to reduce noise. Soft-closing for a quieter close and a steadier slat movement. Minergie certified, mounted in the lintel or as a front installation, hand-operated or controlled by remote, wall switch or smart-home system.

VR 90 90 mm slat width, calmer façade
VR 70 70 mm slat width, needs less room
Clear height (hl)
max. 4,250 mm No minimum height — what matters is that the lintel height (hs min.) is maintained.
Width (bk)
VR 70: min. 410 mm (manual) / 500 mm (motor) – max. 4,500 mm · VR 90: min. 410 mm (manual) / 520 mm (motor) – max. 4,500 mm The minimum width depends on the drive.
Lintel depth (tn)
VR 70: 110 mm · VR 90: 130 mm
Maximum area, single
9 m²
Maximum area coupled, manual drive
11 m²
Maximum area coupled, motor
35 m²
Retract at wind speed
92 km/h (wind resistance class 6)
Source and conditions

Source: Technical Specifications Brochure — Slat blinds, Fabric blinds, Roller shutters, Shutter, edition 03/2026, page 6.

  • No minimum height — what matters is that the lintel height (hs min.) is maintained.
  • From 9 m² upwards a maximum permissible wind speed of 38.5 km/h (wind class 2) must be observed.
  • At 600–1000 mm clear height the stack can be optimised via the h dimension (tsa inside 40–175 mm).
  • Also available with cable guides.

Technical drawings

Section through the lintel with the box dimensions — VR 70
VR 70 Section through the lintel with the box dimensions
Section through the lintel with the box dimensions — VR 90
VR 90 Section through the lintel with the box dimensions
Installation and mounting dimensions
Installation and mounting dimensions

Technical drawings from the Schenker Storen technical brochure, edition 03/2026.

VR composite slat blinds across the whole façade of a roof terrace
Seitliche Profilführung einer VR-Store, Lamellen halb geöffnet Z-förmige Lamellen der VR aus nächster Nähe Helle Lamellen einer Verbund-Raffstore im Gegenlicht

Manufacturer photograph Schenker Storen

The classic slat profile

Convex blind KR 60 / KR 80

The curved slat is the older shape — and often the right one on a period building. It builds very shallow, which makes it the first choice in renovations where there is barely any room in the lintel.

Construction

Aluminium slats, fitted with stainless steel eyelets in the crimp, joined by a Kevlar-reinforced support cord.

Installation

In the lintel, behind a fascia or as a front-mounted unit. KR 80 is also available with cable guides.

KR 80 80 mm slat width, also with cable guides
KR 60 60 mm slat width, especially space-saving
Clear height (hl)
max. 4,250 mm No minimum height — what matters is that the lintel height (hs min.) is maintained.
Width (bk)
min. 410 mm (manual) / 520 mm (motor) – max. 4,500 mm The minimum width depends on the drive.
Lintel depth (tn)
KR 60: 110 mm · KR 80: 120 mm
Maximum area, single
9 m²
Maximum area coupled, manual drive
11 m²
Maximum area coupled, motor
35 m²
Retract at wind speed
92 km/h (wind resistance class 6)
Source and conditions

Source: Technical Specifications Brochure — Slat blinds, Fabric blinds, Roller shutters, Shutter, edition 03/2026, page 9.

  • No minimum height — what matters is that the lintel height (hs min.) is maintained.
  • From 9 m² upwards a maximum permissible wind speed of 38.5 km/h (wind class 2) must be observed.
  • From 3000 mm width, an additional cable guide is needed in the curtain area.

Technical drawings

Section through the lintel with the box dimensions
Section through the lintel with the box dimensions
Installation and mounting dimensions
Installation and mounting dimensions

Technical drawings from the Schenker Storen technical brochure, edition 03/2026.

Even bands of light from a convex venetian blind
Konvexraffstoren an den Fenstern und Balkonen eines Mehrfamilienhauses

Detail photographs Schenker Storen

When the budget has a say

Economy venetian blind EC 70 / EC 80 / EC 100

The same idea, built leaner. Three slat widths and a lower wind resistance class than the composite blind — on a sheltered elevation that hardly matters, on an exposed one it does.

When we recommend it

For several similar windows in a sheltered position, where the number of units counts. Where it is windy we advise the VR — the difference in wind class is not a paper figure.

EC 100 100 mm slat width
EC 80 80 mm slat width
EC 70 70 mm slat width
Clear height (hl)
max. 4,250 mm No minimum height — what matters is that the lintel height (hs min.) is maintained.
Width (bk)
min. 600 mm – max. 4,500 mm
Lintel depth (tn)
EC 70: 110 mm · EC 80: 120 mm · EC 100: 140 mm
Maximum area, single
9 m²
Maximum area coupled, manual drive
9 m²
Maximum area coupled, motor
35 m²
Retract at wind speed
76 km/h (wind resistance class 5)
Source and conditions

Source: Technical Specifications Brochure — Slat blinds, Fabric blinds, Roller shutters, Shutter, edition 03/2026, page 10.

  • From 2500 mm width, an additional cable guide is needed in the curtain area.
  • With cable guides and a lockable bottom rail: hs min. 230 mm or p min. 215 mm.
  • The integrated insect screen is only possible with the 70 mm slat.

Technical drawings

Section through the lintel with the box dimensions
Section through the lintel with the box dimensions
Installation and mounting dimensions
Installation and mounting dimensions

Technical drawings from the Schenker Storen technical brochure, edition 03/2026.

A section of façade with several blinds
Economy-Raffstoren an der Lochfassade eines Bürogebäudes, unterschiedlich weit heruntergefahren

Detail photographs Schenker Storen

Other products

Six systems, one principle.